EXALINK-FUSION-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY, OBJECT-TYPE, Integer32,
    Counter64, NOTIFICATION-TYPE, enterprises   FROM SNMPv2-SMI
    TruthValue                                  FROM SNMPv2-TC
    SnmpAdminString                             FROM SNMP-FRAMEWORK-MIB
;

exaFusion MODULE-IDENTITY
    LAST-UPDATED "201912040000Z"
    ORGANIZATION "Exablaze"
    CONTACT-INFO
        "email:    info@exablaze.com"
    DESCRIPTION
        "MIB for the ExaLINK Fusion"
    REVISION     "201912040000Z"
    DESCRIPTION
        "Updated line-card range to reflect new port index numbering"
    REVISION     "201907160000Z"
    DESCRIPTION
        "Updated port index range to reflect new port index numbering"
    REVISION     "201907020000Z"
    DESCRIPTION
        "Added Counter64 definition, updated previous release date, fixed syntax error"
    REVISION     "201808060000Z"
    DESCRIPTION
        "Added rx and tx port CDR details"
    REVISION     "201703160001Z"
    DESCRIPTION
        "Added rx dropped and link statistics"
    REVISION     "201703160000Z"
    DESCRIPTION
        "Added port statistics"
    REVISION     "201510200000Z"
    DESCRIPTION
        "Added fusion sysinfo"
    REVISION     "201507300000Z"
    DESCRIPTION
        "Added initial traps."
    REVISION     "201504130000Z"
    DESCRIPTION
        "Initial version."
    ::= { enterprises 43296 3 }

--
-- MIB is based on tables, defined as "SEQUENCE of"
-- see RFC2578. This should allow some extensibility
-- in terms of adding features to the data without
-- invalidating existing usage of the MIB.
-- (i.e. avoid hardcoded indicies in the names of objects).
--

fusionInfo OBJECT IDENTIFIER ::= { exaFusion 1 }

fusionInfoSerial OBJECT-TYPE
    SYNTAX      SnmpAdminString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Serial number"
    ::= { fusionInfo 1 }

fusionInfoVersion OBJECT-TYPE
    SYNTAX      SnmpAdminString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Software version number"
    ::= { fusionInfo 2 }

fusionInfoBoard OBJECT-TYPE
    SYNTAX      SnmpAdminString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Hardware type"
    ::= { fusionInfo 3 }

fusionInfoSoftware OBJECT-TYPE
    SYNTAX      SnmpAdminString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Software date stamp"
    ::= { fusionInfo 4 }

fusionLineCardTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF FusionLineCard
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Table of line card information"
    ::= { fusionInfo 5 }

fusionLineCard OBJECT-TYPE
    SYNTAX          FusionLineCard
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "Line card information"
    INDEX           { fusionLineCardIndex }
    ::= { fusionLineCardTable 1 }

FusionLineCard ::=
    SEQUENCE {
        fusionLineCardIndex       Integer32,
        fusionLineCardName        SnmpAdminString,
        fusionLineCardBoard       SnmpAdminString
    }

fusionLineCardIndex OBJECT-TYPE
    SYNTAX          Integer32 (1..255)
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Line card index"
    ::= { fusionLineCard 1 }

fusionLineCardName OBJECT-TYPE
    SYNTAX          SnmpAdminString
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Line card name"
    ::= { fusionLineCard 2 }

fusionLineCardBoard OBJECT-TYPE
    SYNTAX          SnmpAdminString
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Line card hardware type"
    ::= { fusionLineCard 3 }

fusionModuleTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF FusionModule
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Table of internal modules"
    ::= { fusionInfo 6 }

fusionModule OBJECT-TYPE
    SYNTAX          FusionModule
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "Internal module information"
    INDEX           { fusionModuleIndex }
    ::= { fusionModuleTable 1 }

FusionModule ::=
    SEQUENCE {
        fusionModuleIndex       Integer32,
        fusionModuleName        SnmpAdminString,
        fusionModuleBoard       SnmpAdminString,
        fusionModuleFunction    SnmpAdminString
    }

fusionModuleIndex OBJECT-TYPE
    SYNTAX          Integer32 (1..255)
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Internal module index"
    ::= { fusionModule 1 }

fusionModuleName OBJECT-TYPE
    SYNTAX          SnmpAdminString
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Internal module name"
    ::= { fusionModule 2 }

fusionModuleBoard OBJECT-TYPE
    SYNTAX          SnmpAdminString
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Internal module hardware type"
    ::= { fusionModule 3 }

fusionModuleFunction OBJECT-TYPE
    SYNTAX          SnmpAdminString
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Current internal module firmware"
    ::= { fusionModule 4 }

fusionSysInfo OBJECT IDENTIFIER ::= { fusionInfo 7 }

fusionSysInfoLoadAverage OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The 1, 5 and 15 minute load averages multipled by 100"
    ::= { fusionSysInfo 1 }

fusionSysInfoAvailMem OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "System available memory in bytes"
    ::= { fusionSysInfo 2 }

fusionSysInfoNumProcesses OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of current processes"
    ::= { fusionSysInfo 3 }

fusionSensor OBJECT IDENTIFIER ::= { exaFusion 2 }

fusionTempSensorTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF FusionTempSensor
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Table of temperature sensors"
    ::= { fusionSensor 1 }

fusionTempSensor OBJECT-TYPE
    SYNTAX          FusionTempSensor
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "Temperature sensor"
    INDEX           { fusionTempSensorIndex }
    ::= { fusionTempSensorTable 1 }

FusionTempSensor ::=
    SEQUENCE {
        fusionTempSensorIndex       Integer32,
        fusionTempSensorName        SnmpAdminString,
        fusionTempSensorValue       Integer32
    }

fusionTempSensorIndex OBJECT-TYPE
    SYNTAX          Integer32 (1..255)
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Temperature sensor index"
    ::= { fusionTempSensor 1 }

fusionTempSensorName OBJECT-TYPE
    SYNTAX          SnmpAdminString
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Temperature sensor name"
    ::= { fusionTempSensor 2 }

fusionTempSensorValue OBJECT-TYPE
    SYNTAX          Integer32
    UNITS           "Celsius"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Current reading of temperature sensor"
    ::= { fusionTempSensor 3 }

fusionFanSensorTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF FusionFanSensor
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Table of fan sensors"
    ::= { fusionSensor 2 }

fusionFanSensor OBJECT-TYPE
    SYNTAX          FusionFanSensor
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "Fan sensor"
    INDEX           { fusionFanSensorIndex }
    ::= { fusionFanSensorTable 1 }

FusionFanSensor ::=
    SEQUENCE {
        fusionFanSensorIndex        Integer32,
        fusionFanSensorName         SnmpAdminString,
        fusionFanSensorValue        Integer32
    }

fusionFanSensorIndex OBJECT-TYPE
    SYNTAX          Integer32 (1..255)
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Fan sensor index"
    ::= { fusionFanSensor 1 }

fusionFanSensorName OBJECT-TYPE
    SYNTAX          SnmpAdminString
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Fan sensor name"
    ::= { fusionFanSensor 2 }

fusionFanSensorValue OBJECT-TYPE
    SYNTAX          Integer32
    UNITS           "RPM"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Current reading of fan sensor"
    ::= { fusionFanSensor 3 }

fusionPsuTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF FusionPsu
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Table of power supplies"
    ::= { exaFusion 3 }

fusionPsu OBJECT-TYPE
    SYNTAX          FusionPsu
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "Power supply information"
    INDEX           { fusionPsuIndex }
    ::= { fusionPsuTable 1 }

FusionPsu ::=
    SEQUENCE {
        fusionPsuIndex              Integer32,
        fusionPsuType               SnmpAdminString,
        fusionPsuPresent            Integer32,
        fusionPsuTemperature        Integer32,
        fusionPsuPowerIn            Integer32,
        fusionPsuPowerOut           Integer32
    }

fusionPsuIndex OBJECT-TYPE
    SYNTAX          Integer32 (1..255)
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Power supply index"
    ::= { fusionPsu 1 }

fusionPsuType OBJECT-TYPE
    SYNTAX          SnmpAdminString
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Power supply manufacturer and model number"
    ::= { fusionPsu 2 }

fusionPsuPresent OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "True if power supply is present"
    ::= { fusionPsu 3 }

fusionPsuTemperature OBJECT-TYPE
    SYNTAX          Integer32
    UNITS           "Celsius"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Average of current power supply temperature readings"
    ::= { fusionPsu 4 }

fusionPsuPowerIn OBJECT-TYPE
    SYNTAX          Integer32
    UNITS           "Watts"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Current power supply input power"
    ::= { fusionPsu 5 }

fusionPsuPowerOut OBJECT-TYPE
    SYNTAX          Integer32
    UNITS           "Watts"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Current power supply output power"
    ::= { fusionPsu 6 }

fusionPortTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF FusionPort
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Table of ports"
    ::= { exaFusion 4 }

fusionPort OBJECT-TYPE
    SYNTAX          FusionPort
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "Port information"
    INDEX           { fusionPortLineCard, fusionPortIndex }
    ::= { fusionPortTable 1 }

FusionPort ::=
    SEQUENCE {
        fusionPortLineCard          Integer32,
        fusionPortIndex             Integer32,
        fusionPortName              SnmpAdminString,
        fusionPortPresent           Integer32,
        fusionPortHasSignal         Integer32,
        fusionPortEnabled           Integer32,
        fusionPortAlias             SnmpAdminString,
        fusionPortSpeed             Integer32,
        fusionPortRXPackets         Counter64,
        fusionPortRXBytes           Counter64,
        fusionPortRXErrors          Counter64,
        fusionPortTXPackets         Counter64,
        fusionPortTXBytes           Counter64,
        fusionPortRXLink            Integer32,
        fusionPortRXLinkChanges     Counter64,
        fusionPortRXDropped         Counter64,

        fusionPortRXUnicast         Counter64,
        fusionPortRXMulticast       Counter64,
        fusionPortRXBroadcast       Counter64,
        fusionPortRXRunt            Counter64,
        fusionPortRXPause           Counter64,
        fusionPortRX64b             Counter64,
        fusionPortRX65to127b         Counter64,
        fusionPortRX128to255b        Counter64,
        fusionPortRX256to511b        Counter64,
        fusionPortRX512to1023b       Counter64,
        fusionPortRX1024to1518b      Counter64,
        fusionPortRX1519to1522b      Counter64,

        fusionPortTXUnicast         Counter64,
        fusionPortTXMulticast       Counter64,
        fusionPortTXBroadcast       Counter64,
        fusionPortTX64b             Counter64,
        fusionPortTX65to127b         Counter64,
        fusionPortTX128to255b        Counter64,
        fusionPortTX256to511b        Counter64,
        fusionPortTX512to1023b       Counter64,
        fusionPortTX1024to1518b      Counter64,
        fusionPortTX1519to1522b      Counter64,

        fusionPortL1Source          SnmpAdminString
    }

fusionPortLineCard OBJECT-TYPE
    SYNTAX          Integer32 (1..2147483647)
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Line card index"
    ::= { fusionPort 1 }

fusionPortIndex OBJECT-TYPE
    SYNTAX          Integer32 (1..2147483647)
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Port index"
    ::= { fusionPort 2 }

fusionPortName OBJECT-TYPE
    SYNTAX          SnmpAdminString
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Port name"
    ::= { fusionPort 3 }

fusionPortPresent OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "True if a SFP is present in the port"
    ::= { fusionPort 4 }

fusionPortHasSignal OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "True if signal has been detected on the port"
    ::= { fusionPort 5 }

fusionPortEnabled OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "True if the port is currently enabled"
    ::= { fusionPort 6 }

fusionPortAlias OBJECT-TYPE
    SYNTAX          SnmpAdminString
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "Port alias"
    ::= { fusionPort 7 }

fusionPortSpeed OBJECT-TYPE
    SYNTAX          Integer32
    UNITS           "Mbps"
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "Currently configured port speed"
    ::= { fusionPort 8 }

fusionPortRXPackets OBJECT-TYPE
    SYNTAX          Counter64
    UNITS           "Packets"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Number of Ethernet frames received"
    ::= { fusionPort 9 }

fusionPortRXBytes OBJECT-TYPE
    SYNTAX          Counter64
    UNITS           "B"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Number of Ethernet bytes received"
    ::= { fusionPort 10 }

fusionPortRXErrors OBJECT-TYPE
    SYNTAX          Counter64
    UNITS           "Packets"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Number of Ethernet frames received with checksum mismatch"
    ::= { fusionPort 11 }

fusionPortTXPackets OBJECT-TYPE
    SYNTAX          Counter64
    UNITS           "Packets"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Number of Ethernet frames transmitted"
    ::= { fusionPort 12 }

fusionPortTXBytes OBJECT-TYPE
    SYNTAX          Counter64
    UNITS           "B"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Number of Ethernet bytes transmitted"
    ::= { fusionPort 13 }

fusionPortRXLink OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "True if link is detected on the port"
    ::= { fusionPort 14 }

fusionPortRXLinkChanges OBJECT-TYPE
    SYNTAX          Counter64
    UNITS           "State changes"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Link up/down count"
    ::= { fusionPort 15 }

fusionPortRXDropped OBJECT-TYPE
    SYNTAX          Counter64
    UNITS           "Packets"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Number of received packets dropped"
    ::= { fusionPort 16 }

fusionPortRXUnicast OBJECT-TYPE
    SYNTAX          Counter64
    UNITS           "Packets"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Number of unicast Ethernet frames received"
    ::= { fusionPort 17 }

fusionPortRXMulticast OBJECT-TYPE
    SYNTAX          Counter64
    UNITS           "Packets"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Number of multicast Ethernet frames received"
    ::= { fusionPort 18 }

fusionPortRXBroadcast OBJECT-TYPE
    SYNTAX          Counter64
    UNITS           "Packets"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Number of broadcast Ethernet frames received"
    ::= { fusionPort 19 }

fusionPortRXRunt OBJECT-TYPE
    SYNTAX          Counter64
    UNITS           "Packets"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Number of runt Ethernet frames received"
    ::= { fusionPort 20 }

fusionPortRXPause OBJECT-TYPE
    SYNTAX          Counter64
    UNITS           "Packets"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Number of pause Ethernet frames received"
    ::= { fusionPort 21 }

fusionPortRX64b OBJECT-TYPE
    SYNTAX          Counter64
    UNITS           "Packets"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Number of Ethernet frames received 64 bytes in length"
    ::= { fusionPort 22 }

fusionPortRX65to127b OBJECT-TYPE
    SYNTAX          Counter64
    UNITS           "Packets"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Number of Ethernet frames received 65 - 127 bytes in length"
    ::= { fusionPort 23 }

fusionPortRX128to255b OBJECT-TYPE
    SYNTAX          Counter64
    UNITS           "Packets"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Number of Ethernet frames received 128 - 255 bytes in length"
    ::= { fusionPort 24 }

fusionPortRX256to511b OBJECT-TYPE
    SYNTAX          Counter64
    UNITS           "Packets"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Number of Ethernet frames received 256 - 511 bytes in length"
    ::= { fusionPort 25 }

fusionPortRX512to1023b OBJECT-TYPE
    SYNTAX          Counter64
    UNITS           "Packets"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Number of Ethernet frames received 512 - 1023 bytes in length"
    ::= { fusionPort 26 }

fusionPortRX1024to1518b OBJECT-TYPE
    SYNTAX          Counter64
    UNITS           "Packets"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Number of Ethernet frames received 1024 - 1518 bytes in length"
    ::= { fusionPort 27 }

fusionPortRX1519to1522b OBJECT-TYPE
    SYNTAX          Counter64
    UNITS           "Packets"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Number of Ethernet frames received 1519 - 1522 bytes in length"
    ::= { fusionPort 28 }

fusionPortTXUnicast OBJECT-TYPE
    SYNTAX          Counter64
    UNITS           "Packets"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Number of unicast Ethernet frames transmitted"
    ::= { fusionPort 29 }

fusionPortTXMulticast OBJECT-TYPE
    SYNTAX          Counter64
    UNITS           "Packets"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Number of multicast Ethernet frames transmitted"
    ::= { fusionPort 30 }

fusionPortTXBroadcast OBJECT-TYPE
    SYNTAX          Counter64
    UNITS           "Packets"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Number of broadcast Ethernet frames transmitted"
    ::= { fusionPort 31 }

fusionPortTX64b OBJECT-TYPE
    SYNTAX          Counter64
    UNITS           "Packets"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Number of Ethernet frames transmitted 64 bytes in length"
    ::= { fusionPort 32 }

fusionPortTX65to127b OBJECT-TYPE
    SYNTAX          Counter64
    UNITS           "Packets"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Number of Ethernet frames transmitted 65 - 127 bytes in length"
    ::= { fusionPort 33 }

fusionPortTX128to255b OBJECT-TYPE
    SYNTAX          Counter64
    UNITS           "Packets"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Number of Ethernet frames transmitted 128 - 255 bytes in length"
    ::= { fusionPort 34 }

fusionPortTX256to511b OBJECT-TYPE
    SYNTAX          Counter64
    UNITS           "Packets"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Number of Ethernet frames transmitted 256 - 511 bytes in length"
    ::= { fusionPort 35 }

fusionPortTX512to1023b OBJECT-TYPE
    SYNTAX          Counter64
    UNITS           "Packets"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Number of Ethernet frames transmitted 512 - 1023 bytes in length"
    ::= { fusionPort 36 }

fusionPortTX1024to1518b OBJECT-TYPE
    SYNTAX          Counter64
    UNITS           "Packets"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Number of Ethernet frames transmitted 1024 - 1518 bytes in length"
    ::= { fusionPort 37 }

fusionPortTX1519to1522b OBJECT-TYPE
    SYNTAX          Counter64
    UNITS           "Packets"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Number of Ethernet frames transmitted 1519 - 1522 bytes in length"
    ::= { fusionPort 38 }

fusionPortL1Source OBJECT-TYPE
    SYNTAX          SnmpAdminString
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "L1 source port name, if the port has a source of data that is a L1 path e.g. a tap or patch."
    ::= { fusionPort 39 }


--
-- Values passed in Traps
--

fusionTrapValues OBJECT IDENTIFIER ::= { exaFusion 5 }

fusionLidOpenStatus OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "True if the lid is currently open"
    ::= { fusionTrapValues 1 }

fusionFanFaultStatus OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "True if there is a fan fault"
    ::= { fusionTrapValues 2 }

fusionHighTempStatus OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "True if there is a fan fault"
    ::= { fusionTrapValues 3 }

fusionPortUsageStatus OBJECT-TYPE
    SYNTAX          INTEGER {
                        off(0),
                        error(1),
                        unused(2),
                        ok(3)
                    }
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Port usage status, corresponds to right hand LED for port"
    ::= { fusionTrapValues 4 }

fusionPortLinkStatus OBJECT-TYPE
    SYNTAX          INTEGER {
                        off(0),
                        error(1),
                        unused(2),
                        ok(3)
                    }
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Port link status, corresponds to left hand LED for port"
    ::= { fusionTrapValues 5 }

fusionPsuFaultStatus OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "True if there is a PSU fault"
    ::= { fusionTrapValues 6 }

fusionTimeSourceStatus OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "True if a time synchronisation source is available"
    ::= { fusionTrapValues 7 }

--
-- SNMP Trap alerts
--

fusionTraps OBJECT IDENTIFIER ::= { exaFusion 6 }

fusionPowerFail NOTIFICATION-TYPE
    STATUS current
    DESCRIPTION
        "System is shutting down because of power loss"
    ::= { fusionTraps 1 }

fusionTamperAlert NOTIFICATION-TYPE
    OBJECTS {
        fusionLidOpenStatus
    }
    STATUS current
    DESCRIPTION
        "The lid of the device has been opened or closed"
    ::= { fusionTraps 2 }

fusionTempAlert NOTIFICATION-TYPE
    OBJECTS {
        fusionTempSensorName,
        fusionHighTempStatus
    }
    STATUS current
    DESCRIPTION
        "Temperature has gone above or below a threshold"
    ::= { fusionTraps 3 }

fusionPsuAlert NOTIFICATION-TYPE
    OBJECTS {
        fusionPsuFaultStatus
    }
    STATUS current
    DESCRIPTION
        "Power supply has been added or removed, become faulty or returned to normal"
    ::= { fusionTraps 4 }

fusionSystemAlert NOTIFICATION-TYPE
    STATUS current
    DESCRIPTION
        "The system service has restarted"
    ::= { fusionTraps 5 }

fusionFanAlert NOTIFICATION-TYPE
    OBJECTS {
        fusionFanFaultStatus
    }
    STATUS current
    DESCRIPTION
        "A fan has become faulty or returned to normal"
    ::= { fusionTraps 6 }

fusionPortAlert NOTIFICATION-TYPE
    OBJECTS {
        fusionPortName,
        fusionPortLinkStatus,
        fusionPortUsageStatus
    }
    STATUS current
    DESCRIPTION
        "Port link status or usage has changed, corresponds to changes in LEDs"
    ::= { fusionTraps 7 }

fusionConfigUpdateAlert NOTIFICATION-TYPE
    STATUS current
    DESCRIPTION
        "The device's configuration has been changed"
    ::= { fusionTraps 8 }

fusionTimeAlert NOTIFICATION-TYPE
    OBJECTS {
        fusionTimeSourceStatus
    }
    STATUS current
    DESCRIPTION
        "A time synchronisation source has been gained or lost"
    ::= { fusionTraps 9 }

END